    Percutaneous reconstruction of the continuity of a functionally interrupted aortic arch using a stent

    Get PDF
    A case of a 26-year-old man without continuity of blood flow in the level of the isthmus of the aorta is described. During interventional catheterization, we reconstructed this continuity and implanted a vascular stent. (Cardiol J 2008; 15: 80-84

    Symptomatic tachy- and bradyarrhythmias after transcatheter closure of interatrial communications with Amplatzer devices

    Get PDF
    Background: The aim of this paper is to present our own experience related to frequency of symptomatic tachy- and bradyarrhythmias in patients after transcatheter closure of interatrial defects (ASD) and patent foramen ovale (PFO) using Amplatzer plugs. Methods: Transcatheter closure of interatrial communications with Amplatzer devices was carried out on 739 patients in our center. Only patients with new symptomatic arrhythmias (who required pharmacotherapy, cardioversion or pacemaker implantation) were included in to the study. All patients who had had arrhythmias prior to ASD closure, such as supraventricular tachycardias (SVT) or atrial flutter/fibrillation (AF), were excluded. Results: New tachy- and bradyarrhythmias after implantation of Amplatzer devices were observed in 11 patients (1.5%). There were 9 patients (mean age 36.7 years) with atrial tachyarrhythmias (AF in 8 and SVT in 1 patients), which occurred between the first day and 3 months after implantation. Seven patients were treated initially by pharmacotherapy; in 2 of them sinus rhythm returned just after cardioversion. In other 2 patients cardioversion was performed as an initial therapy. In none of these patients, but one recurrence of tachycardia was observed; however, 7 of them had pharmacotherapy prolonged up to 1 year. In 2 patients, aged 15 and 16, complete atrioventricular (AV) block was observed 4.3 and 1.5 years after Amplatzer implantation, respectively. In the first patient intermittent second-degree AV block (Mobitz II) was observed before ASD closure. In both patients, a DDDR pacemaker was implanted. Conclusions: Transcatheter closure of ASD using Amplatzer devices is associated with a risk of new atrial tachyarrhythmias (usually early after the procedure and in older patients). The risk of conduction disturbances such as complete heart block, which can occur in late followup, is low. Thence, close long-term follow-up of these patients is obligatory

    Utility of the dobutamine stress echocardiography in the evaluation of the effects of a surgical repair of aortic coarctation in children

    Get PDF
    Background: Exercise-induced hypertension following repair of the coarctation of the aorta (CoA) is a well known phenomenon. The most important functional parameters in the assessment of the effects of a surgical repair of CoA are the maximal pressure gradient in the descending aorta (GRAD) and systolic blood pressure (SBP). Results of treadmill exercise test using the Bruce protocol (treadmill test) and dobutamine stress echocardiography (DSE) were compared to determine utility of the DSE in the evaluation of the effects of surgical treatment of CoA in children. Methods: The study population comprised of 29 patients, including 20 males and 9 females (mean age 12 years) who underwent a surgical repair of CoA. Changes of the cardiovascular parameters including SBP, GRAD and heart rate (HR) during the treadmill test and DSE were compared. Results: During the treadmill test, SBP at peak exercise ranged from 120 to 230 (mean 163.7) mm Hg, GRAD ranged from 29 to 109 (mean 59.8) mm Hg, and HR ranged from 140 to 188 (mean 169) bpm. At the end of DSE, SBP ranged from 123 to 215 (mean 164.7) mm Hg, GRAD ranged from 29 to 113 (mean 55.4) mm Hg, and HR ranged from 76 to 155 (mean 111) bpm. We found positive correlations of SBP (r = 0.68, p < 0.001) and GRAD (r = 0.82, p < 0.001) values during both tests but no significant correlation for HR (r = 0.42, p = NS). Conclusions: Dobutamine stress echocardiography is useful in the evaluation of the effects of surgical repair of CoA in children

    Przezskórne wszczepienie stentu u 52-letniego pacjenta z ciasnym wrodzonym zwężeniem cieśni aorty i objawami niewydolności serca

    Get PDF
    W pracy przedstawiono przypadek 52-letniego mężczyzny z ciasnym wrodzonym zwężeniem cieśni aorty i z objawami niewydolności serca, któremu przezskórnie wszczepiono stent do aorty. Stan ogólny pacjenta uległ szybkiej poprawie. (Folia Cardiol. 2003; 10: 225&#8211;229

    Application of Cardio-O-Fix occluders for transcatheter closure of patent ductus arteriosus and interatrial communications: Preliminary experience

    Get PDF
    Background: Transcatheter treatment has become the method of choice for treating many heart defects. Recently, Cardio-O-Fix occluder (COF) - a new, self-expandable nitinol wire-mesh device very similar to the Amplatzer device - has been introduced into clinical practice. To the best of our knowledge, this is the first publication related to its application. Methods: Five patients aged from six months to 69 years were included in the study: two with atrial septal defect (ASD), one with patent foramen ovale (PFO) after cryptogenic stroke, and two with patent ductus arteriosus (PDA). These latter two comprised one six month old infant with co-existent hypertrophied cardiomyopathy, and a 53 year-old woman with recanalized PDA after previous ligation. All were treated percutaneously with COF. There was no preliminary patient selection. The only limitation was the size of the devices in our possession (16 and 22 mm ASD COF, 25 PFO COF, 4/6 and 6/8 PDA COF). The implantation technique was the same as previously described for Amplatzer occluders. Results: All procedures were finished successfully with complete closure of the shunt. No complications were observed during a six month follow-up. In the child with PDA, we observed decrease of gradient from 80 to 60 mm Hg in hypertrophied left ventricular outflow tract, although a small protrusion of PDA-COF device was noted in the descending aorta (8 mm Hg gradient in ECHO). In the patient with recanalized PDA, the procedure was performed after arterio-venous loop creation. Mean fluoroscopy time was 4.4 (range from 1.6 to 11) minutes. Conclusions: Our preliminary experience indicates that the application of Cardio-O-Fix devices is safe and effective. (Cardiol J 2010; 17, 6: 607-611

    Nieoperacyjne odtworzenie ciągłości funkcjonalnie przerwanego łuku aorty za pomocą stentu

    Get PDF
    W niniejszej pracy opisano przypadek 26-letniego mężczyzny, u którego stwierdzono przerwanie ciągłości światła aorty w miejscu cieśni. Podczas cewnikowania interwencyjnego odtworzono ciągłość przepływu oraz wszczepiono stent

    Balonowe próby okluzyjne jako kwalifikacja do określonego postępowania terapeutycznego w przypadku złożonych wad wrodzonych serca

    Get PDF
    U chorych po paliatywnych zabiegach operacyjnych z powodu złożonych wad wrodzonych serca często występują trudności związane z ostateczną kwalifikacją do dalszego leczenia. Podjęcie decyzji może ułatwić balonowa próba okluzyjna. Autorzy przedstawiają doświadczenia własne dotyczące tego typu prób u sześciorga pacjentów

    Częstość występowania ubytków przegrody międzykomorowej oraz ich samoistnego zamykania się u dzieci

    Get PDF
    Wstęp: Celem pracy była ocena częstości występowania u dzieci ubytków przegrody międzykomorowej (VSD) oraz ich samoistnego zamykania się. Materiał i metody: Badania przeprowadzono, analizując retrospektywnie materiał Wojewódzkiej Pracowni Echokardiografii Dziecięcej w Opolu. W latach 1992-1999 za pomocą echokardiografii przebadano 3691 dzieci - wadę serca rozpoznano u 675 z nich, a izolowany VSD u 132 dzieci. Średni wiek w momencie ustalenia diagnozy VSD wynosił 3,8 tygodnia. W analizie uwzględniono wielkość, lokalizację ubytku, płeć dziecka, miejsce zamieszkania (wieś, miasto), określając ich wpływ na proces samoistnego zamykania się VSD. Ubytki podzielono na małe, średnie i duże. Wyniki: Ubytki przegrody międzykomorowej stanowiły najczęściej rozpoznawaną wrodzoną wadę serca - były zlokalizowane u 60,1% badanych w części okołobłoniastej oraz u 39,9% osób w części mięśniowej. Większość (67,3%) VSD mięśniowych znajdowała się w dolnej części przegrody. Stwierdzono, że samoistnie zamykały się jedynie ubytki małe (o średnicy poniżej 0,3 szerokości lewego ujścia tętniczego), częściej w części mięśniowej niż błoniastej przegrody (p < 0,001). W pierwszych 6 miesiącach życia zaobserwowano zamknięcie 62% ubytków mięśniowych i 21% ubytków okołobłoniastych. Nie wykazano zależności między samoistnym zamykaniem VSD a płcią i miejscem zamieszkania dziecka (wieś/miasto). Wnioski: Ubytek w przegrodzie międzykomorowej stanowi najczęściej rozpoznawaną ambulatoryjnie wrodzoną wadę serca u dzieci. Wada ta wymaga systematycznego monitorowania klinicznego i echokardiograficznego. Istotna część małych ubytków (głównie mięśniowych) ulega samoistnemu zamknięciu jeszcze w okresie niemowlęcym. Pozostałe wymagają leczenia kardiochirurgicznego, interwencyjnego bądź dalszej obserwacji. (Folia Cardiol. 2003; 10: 785-790

    Przezskórne wszczepienie stentu u 52-letniego pacjenta z ciasnym wrodzonym zwężeniem cieśni aorty i objawami niewydolności serca

    Get PDF
    W pracy przedstawiono przypadek 52-letniego mężczyzny z ciasnym wrodzonym zwężeniem cieśni aorty i z objawami niewydolności serca, któremu przezskórnie wszczepiono stent do aorty. Stan ogólny pacjenta uległ szybkiej poprawie. (Folia Cardiol. 2003; 10: 225&#8211;229

    Balonowe próby okluzyjne jako kwalifikacja do określonego postępowania terapeutycznego w przypadku złożonych wad wrodzonych serca

    Get PDF
    U chorych po paliatywnych zabiegach operacyjnych z powodu złożonych wad wrodzonych serca często występują trudności związane z ostateczną kwalifikacją do dalszego leczenia. Podjęcie decyzji może ułatwić balonowa próba okluzyjna. Autorzy przedstawiają doświadczenia własne dotyczące tego typu prób u sześciorga pacjentów